The functional principle behind the Particulate Matter sensor is based on resistance measurement. Soot particles are deposited on an electrode structure and form conductive soot trails between the electrodes. Prior to each measurement phase, the sensor element is regenerated through heating so that the sensor element adopts a defined status before the start of the measurement process. The DPF diagnostic software then evaluates the functional capability of the DPF using the measured current.